pci-7344. 4-Axis, Stepper PXI Motion Controller Module—The PXI‑7334 is designed for point‑to‑point motion applications. pci-7344

 
 4-Axis, Stepper PXI Motion Controller Module—The PXI‑7334 is designed for point‑to‑point motion applicationspci-7344 4-Axis, Stepper/Servo PXI Motion Controller Module—The PXI‑7344 is recommended for both simple and complex motion applications

I would like to implement control algorithm on PCI 7344 (Don't want to use the built-in PID). Re: PCI-7344 motor interfacing help. There are three cards PCI-7344 with the same behavior. . I am already using one. For my research purpose I need some important information from you. If you are upgrading from a previousHi, How do you reset the encoder count on a servo motor without reseting the position of the motor itself? "Reset encoder count" VI doesn't work. Product Support, I have recently been using a FW-7344 motion controller to drive an experiment. About the 7344/7334 Controller The PCI/PXI-7344/7334 and FW-7344 controllers feature advanced motion control with easy-to-use software tools and add-on motion VI libraries for use with LabVIEW. . 2: I wrote an onboard program that makes a 2axis move and one/two onboard program(s) that write with HighSpeedCapture the Positions to a buffer. lexmotion PCI-7344 with LabView for use as a Parabolic Antenna controller. Hi all, We have a testing machine with three stepper motor actuators. The linear encoders on the motors are. . An introduction to the National Instruments PCI-7344 Motion Controller Featured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms. -While controlling the motors in the "Interactive control" tab, the position. A much better choice is the use of a motion control board, e. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. 付属されていた新しいドライバCDはインストールしましたでしょうか?. When I set it up with the Ni-7344 the drive is ready (green led on drive flashes). This drive is part of an adjustment mechanism which should remain in a stable. If I set the motor's. The PCI Security Standards Council helps protect payment data through industry-driven PCI SSC standards, programs, training, and lists of qualified. The 7344 family of controllers includes the following controllers: • PCI-7344 • PXI-7344 • FW-7344 The 7344 controllers are high-performance controllers for PCI, PXI. National Instruments PCI-7314 Driver Download (Official) The PCI-7314 is a device manufactured by National Instruments. cmd_data This an array of six integers used to send parameters and receive values associated with the execution of the specified command. Initialize your controller. The onboard CPU uses an embedded real-time OS. I have a situation in which the timer_event does not fire. The step/ direction signals from the controller card are converted to phase-drive signals using three UCN5804B stepper ICs, one for each axis, and routed through a 25-pin D-subminiature connector cable to the MAXNC-10. 32. This version of "FlexMotion4. You may be having what is the major reason not to use global variables - a race condition. The PCI-7342 supports buffered contouring mode. The numbers after VEN and DEV indicate the Vendor. I am usi. 5500. Mid-Range Stepper/Servo Motion Controllers 2 AMC GmbH Chemnitz * Tel: 0371/38388-0 * Fax: 0371/38388-99 * [email protected] PCI-7344 with LabView for use as a Parabolic Antenna controller. The 7344 controllers are warranted against defects in materials and workmanship for a period of 1 year from the date of shipment, as evidenced by receipts or other documentation. This warranty includes parts and labor. Please refer to the contouring examples shipping with LabVIEW. The secret is getting the correct Parker-Compumotor Gemini cable that plugs into the. PCI-7344 P70350 drive NI 3 stack Nema 23 Motor P7000 tools used to set the drive steps/revolution to 5000 (microstepping) in MAX and LabVIEW Steps/rev are loaded as 5000 Encoder is resolution is 1000 (so 4000 counts per revolution - verified by killing axis and rotating by hand. Hope this helps, Jorge M. MAX 5. A declassification procedure for each of these boards would also meet my requirements. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. Lai Wechat:17750010683 Whats app:+86 17750010683 Skype:+86 17750010683 QQ: 3221366881 [email protected] there, I would like to trigger my piezoelectric motor more than 100Hz, can I do that with motion controller PCI-7344/PCI-6036E and using while Return to Home Page Toggle navigationThe PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. 10. The PCI‑7334 offers linear interpolation for coordinating multiple axes, real-time system integration for directly communicating with data acquisition or image acquisition hardware, and high-performance stepper generation for ensuring smooth. I set up the axis using MAX. TheSee all Driver Software Downloads. The 7344/7334 family of controllers includes the following controllers: • PCI-7344 • PXI-7344 • FW-7344 • PCI-7334 The 7344/7334. The trigger frequency should be very high (> 4 kHz). Manufacturer: National Instruments. 我目前的系統是PCI-7344 + UMI7764 LabVIEW 8. However, simulating the PCI-7344 will allow you to set up a program to work with a 4-axis motion controller and look into. It includes dual processors, a real-time onboard OS, and multiaxis interpolation. I connect the pins of the control connector of the UMI-7774 (Axis 1) as i describe in the image i attach. NI-DAQmx. The 7344/7334 family of controllers includes the following controllers: • PCI-7344 • PXI-7344 • FW-7344 • PCI-7334 The 7344/7334 controllers are designed for PCI, PXI, and 1394 bus computers. I have one 3 axes(X,Y,Z) mchine. fr>: >Hello, >I've got a PCI card (PCI 7344 for motion control). . It is controlled by a host computer with a PCI-7344 motion controller card from National Instrument. item 5 National Instruments NI PCI-7340 / PCI-7344 Motion Controller Card, 186307C-04 National Instruments NI PCI-7340 / PCI-7344 Motion Controller Card, 186307C-04 $500. lexmotion PCI-7344 with LabView for use as a Parabolic Antenna controller. The target torque can be changed on cerain conditions. While this is happening, I need to change the velocity of one of the motors. In general NI's support answers quickly. BUT, i though that the pci-7344, and the umi-7774 that i have should handle ALL the operations i need to drive the servo. Applications Engineering Group. In addition, a PCI network card connects this MPVIEW to the Internet through the local area network (LAN). The 7344 controllers are warranted against defects in materials and workmanship for a period of 1 year from the date of shipment, as evidenced by receipts or other documentation. 0 are both obsolete, what are some "active" alternatives for this board? And concerning the migration NI-motion 14. In MAX under NI-Motion select your PCI-7344. We are looking for an old PCI 7344 card (4 axis card driving motors) over 15 years old (copyright 2001). The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. In my VI, I have called the Enable Limits. Please call or email us with your request. Not all NI Motion controllers can control a step motor, but the following can: PCI-7332, PXI-7332, PCI-7334, PXI-7334, PCI-7342, PXI-7342, PCI-7344, PXI-7344, PCI-7352, PXI-7352, PCI-7354, PXI-7354, PCI-7356, PXI-7356, PCI-7358, PXI-7358, and PCI-7390. At this point, NI Motion will only operate in LabView 32-bit independant of 32-bit or 64-bit OS. 1) When I am stationary and command a Halt, there is a resulting jerk movement, sometimes up to a few 1000 servo steps. Shut down your computer. T. You won't be able to achieve these types of signals with a 7344 motion control board. (67 pages) Controller National Instruments 7932 Manual. 1 and the LabVIEW version is the 8. The PCI-7334 is the NI low-cost stepper-only motion controller, which offers the flexibility and ease-of-use features found throughout the FlexMotion line of controllers. No worries Chris. It is built using off-the-shelf components (Galil servo motors, PWM power amplifiers with torque-control mode, Lintech manipulator, standard camera). hwdb hwdb/20-pci-vendor-model. JB. Order toll free: 800. また、NIのホームパージから. We used NI vision (IMAQ PCI-1409), motion controller (PCI-7344), and DAQ (PCI-6025E) cards for this MPVIEW. Indeed, when we use a newer PCI7344 card, we have driver / firmware compatibility issues. Re: PCI/FW-7344 Motion controller either isn't found or when it is, MAX crashes depending on which version of NI-Motion, DAQ and. The PCI‑7344 also provides contouring capability for complex moves. I don't see a good way to control 5 motors with this board. STL file there are 28 layers/faces. Servo motors expect a pulse every . However, simulating the PCI-7344 will allow you to set up a program to work with a 4-axis motion controller and look into. We used thirty-five digital I/Os for a variety of purposes, including safety interlocks, proximity switches, and optical sensors. How can. 2. In the second part, you. Go to the Axis Configuration option, under the desired axis (e. I have PCI-7344 and PCI-6023E and I want to synchronize them so that my DAQ card will start and stop the acquisition definitely when the motion start and stop. Due to synchronization constraints I need hardware scanning synchronized with some internal clock instead of software scanning using a set. The 7344/7334 controllers are designed for PCI, PXI, and 1394 bus computers. Is there a way to reduce this time delay?I am trying to operate NI Motion with a PCI-7344 card inside LabView 64-bit on a WIN7/64 platform. 08-21-2009 03:04 PM. ) Issue: W. Featured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID loop update rate, the National Instruments PCI-7344 (Part number: 778916. . Using the X-Y Grid Inspection (Template). And see the result. All of 3 motors require +5V 24mA for the Mike encoder. PCI-7342 National Instruments PCI-7342 2-Axis Stepper/Servo Controller Card from National Instruments | Buy Today from Artisan. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. The PCI-7344 is a motion control board that requires the NI-Motion driver software. Giridhar, everything is ok with your 7344. ), I configure a sequence (in the sequence tab"Find Reference Settings )that the motor finds my" home switch ". controller in the 7344 family and contains information concerning their operation and programming. Re: LabVIEWアップデートに伴うPCI-7344のエラー. . Hi all, I'm using the PCI-7344 board and I'd like to trigger an external device. After this software upgrade, several things changed. 6: Cấu trúc của máy phay CNC. A few month ago, i tried the same, but i lost the code and the motor moves so that the analog signal goes to 0V. Page 1 PCI-7334. 240 MHz signal. Featured with advanced motion control, handy software tools, and motion VI libraries (to be used with LabVIEW), the NI PXI-7344 (Part Number: 777935-01) is a 4-Axis, PXI Stepper/Servo Motion Control Module. Right now, the +5V pins connected through an amplifier board to the "Host +5V" pin#59 in Motion I/O Connector of PCI-7344 board. 0 and NI-Motion 7. Without seeing the program, it's impossible to tell but execution highlighting and single step mode changes the way the program executes and. am rules/80-net-setup-link. 445 subscribers. I have tried all the Settings discussed in the Forums and they still don't run. The code is similar to the following: Timer1_Timer() Check the status of the I/Os on the PCI-7344 and update as necessary If Input1 is 'on' the set Input1=T. I am trying to control a servo motor using an analog feedback connected to analog input 1 on the PCI 7344 board. I am a Master’s student of International Islamic University Malaysia. Member ‎08-12-2003 06:30 PM. This motion controller can control upto 4 servo motors and can give 2 PWM. I am a Master’s student of International Islamic University Malaysia. freedesktop. When i am using PCI Flex-6C,Finding home functions does not work as the PCI 7344 do, The controller stops axis 1 and axis 2 during the finding home sequences when the axis 3 encountered home switch first. The PCI‑7344 also provides contouring capability for complex moves. When calling "DIO Port Config. Shut down your computer. In the second part, you program for the PCI-7344 controller, which adds several advanced features including the ability to run onboard programs. National Instruments PCI-7344 Motion Controller Device. Trusted Seller. Bgrain, there is no way to tweak a PCI-7344. Each axis uses 2 Synchro's (1:1 & 36:1 for Course & Fine 90V / 60Hz) for feedback. Fast Quotes & Shipping. I triggered the Measures over RTSI0 with 50Hz(for a. The motor is fitted with two encoders, both with A, B and Index. Each axis uses 2 Synchro's (1:1 & 36:1 for Course & Fine 90V / 60Hz) for feedback. A National Instruments PCI-7344 4-axis controller card that resides in a PCI slot in a Windows PC controls motion. The PCI‑7344 also provides contouring capability for complex moves. . I am using the PCI-MIO-16XE-50 and PCI-7344. The event never seems to fire. (NI). The onboard CPU uses an embedded real-time OS. Installing/reinstalling LV or CVI doesn't necessarily install NI-Motion. 8 Ghz, 4 Gb Ram, Matrox Pahelia Video card (agp), PCI-7344 and FW-7344 (Firmware version 6. I'm testing angle sensors whose voltage output is proportional to (you've guessed it. PLEASE, i appriciate any help, because its not working. Hi, I am running a motor using the PCI 7344 motion control board and a MID-7654 servo with encoder feedback. The 7342 follows this position profile using a spline algorithm. I'm stepping the motor round by one step, checking that it's got there by reading the encoder, measuring the sensor voltage and repeating. 2 version but I can't be initialize the motion card in MAXDiscontinued NI motion products (PCI/PXI-7334) Affected model numbers include: PCI-7332; PCI-7334; PCI-7342; PCI-7344; PCI-7352; PCI-7354; PCI-7356; PCI-7358Issue Details I have a PCI-7344 with a UMI-7774 and a Yaskawa Servo Motor and Driver. I am using LabVIEW 2014 and NI PCI 7344(motion controller). i just need to know if what i write here is correct. • PCI-7344 • PXI-7344 • FW-7344 • PCI-7334. Is it possible to realize such a sample rate with breakpoints and an onboard program like: "Modulus Breakpoint (on-board re-enable). 1 were installed. Is there any way to change the velocity while still col. Conventions National Instruments PCI-7344 Motion Controller Device. The National Instruments PCI-7342 / 7344 also provides contouring capability for complex moves. The NI 73xx Motion Controllers use the NI-Motion drivers, and do not appear to support IVI (necessary to use Instrument Control toolbox) or NI-DAQmx (necessary for access from Data Acquisition toolbox). 0 Kudos Message 1 of 7 (4,209 Views) Reply. This warranty includes parts and. 3. 25 ms corresponding to 0 degrees, 1. Feedback is a incremental encoder 16404counts/rev (400counts/mm). This warranty includes parts and labor. To research general control behavior this might be ok but if you want to use FieldPoint in a real-world application you should figure out if the PID loop is fast enough for you. The Problem is feedback from each axis (AZ & EL). Running the motor is not a problem but when it has stopped (there is no load) the servo system still puts out a lot of voltage (+-48V) all the time. The PCI‑7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. . The capture method is configurable. I don't see a good way to control 5 motors with this board. The Stepper Motors on My machine don't move on my machine, I have PCI -7344 card connected to UMI 7764 with 68 pin connector. This axis don't have to make rapid movements, instead I'm looking for accurate speed and mostly rotation in one direction only. Using MAX to test the. The 7344/7334 controllers are warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming. 1) How do i know if this motor drive is compatible with the pci-7344 and umi7774 ? for example: inside the UMI manual is written that the Motor drive must support "Sinusoidal Commutation" i. I'm programming a 3-axis piezo stage to do fast scanning (128x128 points in ~ 5 seconds) with a PCI-7344. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Trusted Enthusiast. Country/Region of Manufacture. We are using PCI 7344 and UMI 7774. 1 before, and it is really weird. I have seen a few other places where people have asked to do this but have found other solutions. Does this give you any clues? So you are saying this is a bug which was fixed with a patch in earlier LV versions? I didn't find any documentation on this. In our system, a high resolution encoder works as the feedback sensor, and a third-party of servo works as the velocity loop controller. As the control loop is typically running much slower on the FP system compared to the PCI-7344, you will have to modify the PID parameters accordingly. PCI/PXI/FW Installation Complete the following steps to install your PCI/PXI/FW motion controller: 1. , Austin, Texas) installed in a supportive PC station are integrated using a LabVIEW software package (National Instruments Co. A NI PCI-6527 48-bit digital I/O board that resides in another PCI slot inside the PCHello, I am trying to find out what type of switches will work with PCI-7344 (4-Axis Stepper/Servo Controller for PCI) limit and home inputs. Configure your stepper settings. 1. Hi, I'm using PCI-7344 & UMI 7764 to control dc motor on servo mode, but i have a question, when i define contouring points that value was smallerHi, i have PCI-7344 and UMI-7774 that i want to connect to this Servo motor drive of Yaskawa. Also try to update firmware, by updating the ni-motion driver, and then go to MAX and click PCI-7344, and then in the right window click the firmware tab, and then click update firmware. In the Stepper Settings tab (near the bottom of the screen), select your Stepper Steps Per Revolution, Stepper Loop Mode, Stepper Polarity, Stepper Output Mode, and Pull-in Tries. 0. I've never used LabVIEW 6. When I was performing some tests in MAX, I realized that I don't have feedback from axis 2, 3 and 4. If you are installing the FW-7344, connect the controller to your computer’s IEEE-1394 port. Product Support Resources. Solution. The 7344 controllers are a combination of servo and stepper motor controllers for PCI, PXI, and 1394 bus computers. PCI-7390 Driver. sooner or later hardware will be discontinued, OS end of life, LabVIEW version not supported, etc. The 7334 controllersHello, We are planning to build a tie rod fatigue test system with Labview and NI PCI-7344 4-Axis Motion Control Board. 75 ms corresponding to 180 degrees. We facilitated the wiring of inputs to each of these components with NI SCB-68 digital I/O connector block and the UMI-7764 motion interface. So, am I missing something ?, All the motors are 3rd Party. Motion Control 7344 Hardware User Manual 7344 Hardware User Manual July 1999 Edition Part Number 322504A-01. 像是PCI-7344的STEP馬達要設定成position mode,而servo馬達要設成velocity mode這類的。而關於PCI-7344的設定值怎麼設定,. Periodically the servo system does not work. I have one 3 axes(X,Y,Z) mchine. I am using a 4096 step per revolution encoder with a UMI-7764 connected to a PCI-7344. Hello, After having configured mu board PCI-7344 under MAX software (1axis activated because 1 only axis used, standard of stepper in open Loop. It is compatible with PCs running Windows XP, among other operating systems. The strangest part of all this is that I rarely saw modal errors and now they are becomming common and the VIs have not changed. I have verified the connection is working. Seller assumes all responsibility for this listing. Is there a way to synchronize motion data (PCI-7344) with AI data? I was hoping that I could capture the position by RTSI to a spare AI channel, but it appears that the position capture functions store the data internally. This controller is designed for PXI, PCI, and 1394 bus computers. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. To facilitate learning, we mounted all the motion controlled items, such as three power supplies, two torque amplifiers and oneDescription. I continue to get more and more modal errors from the board. Chapter 5 Signal Connections Analog Inputs The 7344/7334 controller has the following ADC input signals: • 7344/7334 Hardware User Manual Analog Input <1. About the 7344/7334 Controller The PCI/PXI-7344/7334 and FW-7344 controllers feature advanced motion control with easy-to-use software tools and add-on motion VI libraries for use with LabVIEW. 08-10-2007 01:26 AM. it is going to be sqaure wave signal . After the update the card was not anymore detected in MAX. いつもお世話になっております。 daqの外部クロック読み込みについて質問があります。 現在、pci-7344およびpci-7764を用いて、サーボアンプからのエンコーダ信号を読み取り、この信号を外部クロックとして、pci-6221に入力する電圧を読み取りたいと思っています。Im using a UMI-7774 and a PCI-7344 motion controller with a Compax C3 servo drive. I have no choice in using synchro's as feedback. I initialise it using NI MAX (version 2. 能否用NI运动控制卡读取非正交编码器? 硬件: Motion Control>>Controllers>>PCI-7344, Motion Control>>Controllers>>PXI-7344, Motion Control. I checked the files that the person shared with me which are NI-Motion configurations. controller in the 7344 family and contains information concerning their operation and programming. Feel free to check it out here. There was a "broken" device PCI-7344 under NI Motion Devices, which status said something like "This device has been removed or could not be detected" and the Reset command said something. This bus offers high-speed and efficient connectivity between different products from National. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. We have been trying to control the velocity and position of our servomotor but regardless of what values we put in the motor always moves at about 500 rpm and travels about -31000 cnts before stopping. I have verified the connection is working. Two of the four linear motors drive the parallel tracks in an H-Bridge (X and X') The third linear motor drives the crossbar. Re: problems with a PCI-7344 motion controller. g. In Windows Device Manager, right-click on the PCI Simple Communications Controller and select Properties . Member. The parameters of that algorithm can be modified, but the algorithm itself is fixed. command This is one of the commands described below. . Single-board rio oem devices (50 pages) The PCI-7344 is not a working device but something I created to explore the change board ID option. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and. 5,控制方式采用的是位置控制模式. Re: PCI-7344 motor interfacing help. Without seeing the program, it's impossible to tell but execution highlighting and single step mode changes the way the program executes and you. 0 - NI PCI-7344 GPIB Card - NI MID-7604 Stepper Motor Drive - US Digital HB6M Rotary Incremental Encoders I am attaching the VI's we are currently using to control the motors. In the Details tab, when selecting the "Device instance path" or "Hardware Ids" Property, there should be an entry similar to PCIVEN_XXXX&DEV_XXXX&. The motors are 2 phase and have a 1. return to the previous setup which has NI-Motion 6. FlexMotion 5. . The Payment Card Industry (PCI) Data Security Standards (DSS) is a global information security standard designed to prevent fraud through increased control of. start using the board! The best place to see that is the readme files, and I see that for your board (7344), the correct version would be 5. Hungary. Features The 7344 controllers are a combination of servo and stepper motor controllers for PCI, PXI, and 1394 bus computers. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 00 +$12. 8 degree pitch (200 steps per rev). 1, PCI-7344, Amplifier MID-7654, 4 motor-encoders. The pulse should last from 1. We have just recently switched to a new hardware revision and now all boards don't show up with their specific names but with the name of the board family: Board Family Specific Boards. the drive feeds back a simulated. I am using a PCI-7344 card with LabView to control a 3-axis servo motor motion system in conjunction with a data acquisition system. Hello, I am using a PCI-7344 motion controller card to drive 2 stepper motors in closed loop mode. activate the INH output via software. There are no. At Lektronix we can provide you with a brand new National Instruments PCI-7344 covered by the Original Manufacturers Warranty. The National Instruments PCI-7342 / 7344 also provides contouring capability for complex moves. Servo motors expect a pulse every . Sacha, with the built in controller all you have to do is to wire a serial cable to the serial port of your PC and the drive and use VISA functions to send ASCII commands to the device. The 7344 controllers are warranted against defects in materials and workmanship for a period of 1 year from the date of shipment, as evidenced by receipts or other documentation. Options. I would appreciate if you can suggest me any research that I could do on this system which involve 3 axes motion -using all ac servo motor (automated storage and retrieval system) - I. But. When I was using a Motion Controller such as the PCI-7344 which uses the Motion driver, it was possible to save all the motor settings in a . 1. Right now I have completed the wiring of feedback from motor encoder and managed to see encoder readings in MAX. It breaks out the signals available from the PCI-7344. 0 and NI-Motion 7. Now I meet a problem about limit switch----That's PCI 7344 can't detect the limit switch's status if I set the motor's velocity a little faster(for example,1500RPM). 问题:. 1. 00 shipping And i want to connect it to UMI-7774 with PCI-7344 also configured in MAX to work in P-Command mode. . The NI-Motion version is 7. My application requires 6 axis and hence I want to use two PCI 7344 motion controllers. . Figure 7. The onboard CPU uses an embedded real-time OS. For my research purpose I need some important information from you. I would like to implement the same thing using FP & Softmotion instead of 7344 board as later I would like to implement fuzzy logic control into softmotion. . PCI-7344 PXI-7344 PCI-7352 PXI-7352 PCI-7354 PXI-7354 PCI-7356. . PXI-7344 PXI/CompactPCI PCI-7344 PCI FW-7344* IEEE-1394 * Windows 2000/Me/98 only. g. My requirement is 1 Khz samples . The third axis (#3) is counting properly but not finding the index. Would I use seperate loops, for the seperate servos? can I write to the PCI 7344 from three loops simultaneously? does a. For my research purpose I need some important information from you. 10-27-2001 03:20 PM. . Features The 7344 controllers are a combination of servo and stepper motor controllers for PCI, PXI, and 1394 bus computers. 展开 设备和接口 树. I am using LabVIEW 2014 and NI PCI 7344(motion controller). Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. We presented a solution using the NI PCI-7344 four-axis stepper and servo motion controller using LabVIEW as the main user interface. Don't want to physically move the motor to zero out the encoder. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Options. If you are using LabVIEW, there are many example programs that ship with the NI-Motion driver. Regards, Shut down the system and physically remove the PCI-7344 from the system (important to remove resource locks). 445 subscribers. 25 ms to 1. . 8. NI 7350 NI 7352, NI 7354, NI 7356, NI 7358. Remote Printing. . can we get the VI for oscillator with variable frequency from 10 khz to 1 Mhz with variable duty cycle. 我使用的硬件是PCI-7344,UMI-7764,Sanyo 伺服驱动器和伺服马达一套 运动控制卡的驱动是NI-Motion7. Reply value associated with the本系统以PCI-7344为基础,通过 NI公司最新的LabVIEW8. Summary of Contents for National Instruments 7344 Series. I have verified the connection is working. Can I configure another one in the same PC to add more axes to my current system. 1 Release Notes 4 ni. Especially, the hardware upgrade option is something great. PCI/PXI/FW Installation Complete the following steps to install your PCI/PXI/FW motion controller: 1. The PCLK (or Pulse Clock) line can also be used to input your own clock which is divided down by 256 or 32,768 depending on what you select in. . The DISABLED LED of the Axis1 - Axis4 on the e UMI is not Lit, i also notice that in MAX under Motion IO setting, the "inhibit input setting" is grayed. Manufacturer: National Instruments FW-7344, 4 Axes, 9 to 25 VDC, Stepper/Servo Motion Controller National Instruments FW-7344 Stepper/Servo Motion Controller The FW-7344 (Part Numbers: 186839C-01, 778113-01) is a Stepper/Servo Motion Controller. 0) hangs. Use a lower resolution stepper motor. 288. 25 ms to 1. Connected to this is a Pepperl & Fuchs 1024 line encoder. Sorry but I can't give you any further help. 4-Axis, Stepper Motion Controller Device—The PCI‑7334 is designed for point‑to‑point motion applications. 3. Options. 2的强大功能,我们得以 在短时间内完成了控制系统的开发,同 时保证了机械臂的运动精度与负载能 力。The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. Mark as New; Bookmark. nce-file would it be possible to do the same thing with a C Series Motor Interface Module that uses the SoftMotion driver such as the NI 9514?PCI-7334 PCI-7344 Software. we are using PCI 7344 and labview 7. Motion control (52 pages) Controller National Instruments 7344 Series User Manual. The National Instruments PCI-7342 / 7344 also provides contouring capability for complex moves. I did it: 68331 from 7. Use a higher resolution encoder. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments.